Hotbox type HBs, range of performance Print

Type

HBs1

HBs2

HBs3

Fuel

Oil

Gas

Oil

Gas

Oil

Gas

Heating capacity [KW]

80

68

160

136

240

204

min. volume flow [l/min]

13

10

26

20

39

30

max. volume flow [l/min] *

20

17

40

34

60

51

min. water temp. [°F] 

140

140

140

140

140

140

max. water temp. [°F]

203

203

203

203

203

203

* If the value exceeds the maximum volume flow, problems with  condensation may occur.   Remedy by a condensation outlet on the ground of the combustion chamber.

Temperature diagram

Temperature diagram

————  oil heated
− − − − −  gas heated

The temperature diagram shows the expected temperature rise.

Due to tolerances of production the shown temperatures can vary by ± 15 %.

Pressure ranges

  1. High pressure range, 20 – 500 bar

      Designed for connection to a high pressure pump. Thus the combination becomes a fully functioning hot high pressure cleaner.
    (Attention: This is available only in combination with 3/8“- heating coils !)

  2. Low pressure range, 4 – 20 bar

      Designet for connection to a water pipe or to a corresponding centrifugal pump. Thus a powerful flow heater is at your disposal. Minimum flow pressure 4 bar.
    (Attention: This is available only in combination with 1/2“- heating coils !)

Hotbox- Variations

From the tables you can use various combinations according to your requirements considering  the following points:

1. Capacity requirements and water quantity

See table and diagram above!

2. Pressure range

See Variations Variations

3. Equipment of combustion chamber
    230V / 110V AC

Heating coil made from steel or stainless steel,

casing made from galvanized steel or stainless steel,

bio diesel equipment, see Variants Variants

4. Equipment of combustion chamber
    12V DC

Heating coil made from steel or stainless steel,

casing made from galvanized steel or stainless steel,

bio diesel equipment, see Variations Variations
5. Way of mounting

wall or ground mounting, see Mounting possibilities

6. Air intake

From inside the installation room or from the outside,
see Examples Examples

7. Cover

with or without cover, see Variations Variations

8. Dimension and weights
see Data sheet Data sheet
9. Technical data
see Data sheet Data sheet

 